The system
The thermostat: one per room, and that is all there is to set.
No boiler to set, no valve, no heating curve. Each room has its own thermostat, which switches the film on when it is too cool and off as soon as it is warm enough.
What it does
The thermostat measures the room temperature. Below the set temperature, it powers the film; as soon as that temperature is reached, it switches it off. According to the manufacturer, the gap between the two is half a degree.
There is nothing else to set: no flow temperature, no balancing, no boiler. This room-by-room control is one of the reasons the manufacturer gives for a short running time: 40 to 90 minutes a day on average over the year according to its page on main heating, 1 to 2 hours a day depending on the building according to its technical data.
In France, a programmable thermostat is becoming compulsory in all homes: for new buildings whose permit is applied for from 1 January 2027, and on 1 January 2030 for existing homes. It must offer at least four settings: comfort, setback, frost protection and off. The manufacturer’s is programmed by the week, room by room, with an economy mode and a frost protection mode.
What the manufacturer’s thermostat can do
| Function | What the manufacturer states |
|---|---|
| Setting range | 5 to 35 °C |
| Measurement | built-in sensor; optional floor sensor, as a limiter |
| Programmes | weekly, economy, frost protection from 5 to 15 °C |
| Open window | detected |
| Reheating | adaptive start |
| Consumption | displayed per room, over 7, 30 and 365 days |
| Connection | 2.4 GHz Wi-Fi and app |
| Switching capacity | 16 A at 230 V |
| Protection | IP30, class II |
| Size | 86 × 86 × 16 mm, in a flush-mounting box at least 35 mm deep |
Where to put it
- On an internal wall, between 1.2 and 1.5 m from the floor.
- Away from windows, doors, air vents and direct sunlight: it would measure something other than the room.
- Outside wet areas. In a bathroom, it goes out of reach of splashes, or in the hallway.
One circuit per room
Each room has at least one heating circuit, on its own electrical line, protected at the consumer unit. A thermostat switches 16 A at most, that is about 3.6 kW: around thirty square metres of film at 115 W/m², around twenty at 180 W/m². Beyond that, we fit several thermostats, or one thermostat and a contactor.
The connection and the circuit protection are an electrician’s job, to the standard of the country.
How to set it to use less
The manufacturer gives a simple rule: heat only when you are there.
- At night, and during a long absence: 17 to 18 °C.
- An absence of more than an hour: 2 to 3 °C less.
- Reheating: programmed 30 to 45 minutes before the time when the room needs to be warm.
- Never below 15 °C, and better, not below 17 °C: a room that is too cool becomes damp, and a damp room needs more energy to warm up again.
Its reasoning: the warmer a room is, the more heat it loses through its walls and windows. Turning it down when it is empty is therefore a saving, provided the heating brings it back up quickly. That is the case here, it says: there is no screed to reheat first. The French regulatory calculation does not take up this argument: on the contrary, it counts electric underfloor heating as benefiting less from temperature setbacks than convectors, without distinguishing a thin film from a cable embedded in a screed.
ADEME, the French agency for ecological transition, gives an order of magnitude: one degree less on the set temperature means on average a 7% saving on the heating bill.
The thermostat displays the consumption of each room. From the first winter, you see what your settings change. The manufacturer’s readings, building by building, are on the measured consumption page.
What it does not take care of
- Hot water. The system heats the rooms; the water has its own water heater.
- A badly sized room. The thermostat switches on and off; the output is decided at the design stage, room by room. The sequence is on the page fitting, step by step.
Frequently asked questions
Your questions on this subject.
Is a sensor needed in the floor?
The manufacturer does not provide for one: the floor surface stays between 20 and 24 °C, and the thermostat measures the room temperature. It accepts a floor sensor as a limiter, if the manufacturer of your floor covering asks for one.
Can the heating be controlled remotely?
Yes, according to the manufacturer: the thermostat connects to the home Wi-Fi and to an app. It can also be set by touch, on its screen.
What happens if a thermostat fails?
Only its room stops heating; the others carry on. According to the manufacturer, it is replaced in a few minutes. It is on the wall: the floor is not affected.
How far should I turn it down when I am away?
The manufacturer advises 17 to 18 °C at night and during a long absence, and never less than 15 °C, to rule out the risk of condensation.
Does a large room have several thermostats?
Beyond about 30 m² of film, yes: a thermostat switches 16 A at most. We then fit several thermostats, or a single one that controls several circuits through a contactor.
Can it be linked to a home automation system?
According to the manufacturer, KNX integration is possible. Say so at the design stage.
Read next
- The carbon systemA 0.45 mm carbon film that heats across its whole surface, under your floor covering. Build-up, outputs, temperatures and limits, according to the manufacturer.
- Measured consumption15 to 50 kWh per m² per year according to the manufacturer, median 24. Its eleven meter readings, building by building: what they prove, what they do not prove.
- Fitting, step by stepBefore, during and after the fitting of carbon underfloor heating: the design, the steps on the day, the times stated by the manufacturer, what to prepare.
- Warranty and certificationsTÜV NORD CERT type examination, CE marking, pollutant testing, patent, the manufacturer's 20-year warranty: what each document proves, and where to check it.
Got a heat pump quote sitting on your desk?
One call, and we send you the Carbosol equivalent for the same area, on one page. Free, and without us calling you back every three days.
-
Call AndreiFrançais · English · Русский +33 6 82 57 93 38
-
Call ThomasFrançais · Deutsch +33 7 65 16 89 79
Call back within 24 hours on working days Write to us